Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8851087

- Product Categories
- Friendly Links
- home > Supply > Blood Pressure Monitor Arm Blood Pressure Monitor home blood pressure monitor elderly factory direct with sphygmomanometer
Blood Pressure Monitor Arm Blood Pressure Monitor home blood pressure monitor elderly factory direct with sphygmomanometer
Information Name: | Blood Pressure Monitor Arm Blood Pressure Monitor home blood pressure monitor elderly factory direct with sphygmomanometer |
Published: | 2012-10-30 |
Validity: | 120 |
Specifications: | |
Quantity: | 100000.00 |
Price Description: | |
Detailed Product Description: | Order Hotline: 13728829150 Mr. King, the specification of this model sphygmomanometer automatic electronic sphygmomanometer for arm measurements, can be quickly and easily measure blood pressure and pulse. ※ This model the electronic sphygmomanometer can not be used for child care. Product Introduction: Most people entering in the elderly, blood pressure generally there will be increased tendency, so we should be aware of, whether self-blood pressure in a healthy state. The body's blood pressure all the time in the fluctuations, and therefore develop a regular basis in the habit of measuring blood pressure, is indispensable in our day-to-day health management. The Model sphygmomanometer for automatic electronic sphygmomanometer for arm measurements quick and easy measurement of blood pressure and pulse. Starting with voice shall also voice broadcast prompts, suitable for home use, especially the visually handicapped and the elderly, the measurement methods similar to traditional mercury sphygmomanometer, measured brachial artery band put their arm to the upper arm, and its measurement stability better than wrist blood pressure monitor, and more suitable for older, arrhythmia, diabetes-induced peripheral vascular aging patients. Gift than to send health, this product is the best choice for gifts in the elderly, a middle-aged friends care use (a) Insert the batteries ● Be sure to use alkaline batteries ※ Be sure to use alkaline batteries The hosts turn over the direction of the arrow to remove the battery cover. 2 Make sure the pole of the battery, loaded AA (5), 4 alkaline batteries. 3 Close the battery cover until you hear the "click" sound. Following replace the battery, replace the battery ● The figure shows the measurement process. ● "ON / OFF" key is pressed, the LCD screen without any display. Battery life ● use a new set of alkaline batteries, about 300 measurements. (Ambient temperature of 22 ° C, pressure 180mmHg, arm circumference 17cm) ● If the ambient temperature is low, it will shorten the battery life. ● alkaline batteries are charged, placed in improper positive and negative, short-circuit, mixed with used batteries or different types of batteries in a fire medium may cause leakage or rupture. Do not disassemble the battery. This device is not in use for a long time, remove the batteries should sphygmomanometer. ● waste battery Do not throw attention to recycling. Measurement ● measurements in the relaxed state of body measurements, can not smoke, take a deep breath, talk and peristalsis, otherwise it will affect the measurement results. 1) Press the power button (the voice prompts Note) ● ● Full press the power button for about 2 seconds. ● Automatic from 0mmHg start the pressure. ● gradual increase in pressure measurement. ● pulse is detected, the heart symbol flashes 2) the end of the measurement display blood pressure values, pulse rate ● arm with air discharge. ※ measured values ??in the hypertension field, accompanied by acute and short beeps, the measured values ??in the normal field, accompanied by the sound of a beep long. ※ measured pulse rate is based on a translation value. V. 1. Correct use of to ① the elbow on the table ② the arm band and the heart is highly consistent ③ clothes Do not be involved in the arm with ④ palms up, relax the body, straight 2. creating a stable environment: ① morning calm relax ② No ③ room temperature when the toilet is intended, the ④ quiet 20 degrees Celsius, the surrounding noise place. 3 at the same time every day for blood pressure measurements: blood pressure is often in the changes, can not rely on the results of a blood pressure measurement to determine the blood pressure condition, only according to the number of measurement data over a period of time before more reliable. Therefore, daily measurement of blood pressure, select a day in the mood to keep the time period of the most stable state (such as getting up early in the morning), the ideal approach is to every day, as far as possible, at the same time is measured. (B) the readings of the blood pressure values: the World Health Organization systolic blood pressure (hypertension) is higher than 140mmHg or diastolic blood pressure (low pressure) is higher than 90mmHg that is called hypertension. Is generally believed that the systolic blood pressure lower than 90mmHg or diastolic blood pressure below 60mmHg, called hypotension. Hypotension can cause tissue blood perfusion deficiency, leading to cell hypoxia, prone to dizziness, fatigue, severe palpitations, dizziness and other symptoms appear. Re-measuring the symbol "E #" (# value can be 0, 1, 2, 3, 4) continue to measure, press the power button to temporarily cut off the power, be sure to wait for 4 to 5 minutes, and then measured. (C) to call up the stored measurement data stored measurement value, the state cut off the power, still adjustable measuring value. 1 Press the memory button, full bright display then displays the first set of memory. 2 Press the memory button every time you press the memory button, new data, alternately display when no data is not displayed. ※ Please press the memory button every fast Press more than 3 seconds, the measured value stored will eliminate all, pay particular attention to Note 1 Do not unauthorized repair, demolition and renovation; 2. do not host Shuaidiao the on the ground against collision or strong impact; Do not be sphygmomanometer from 0 ℃ place immediately after removing the use at least for 1 hour in a warm environment; 4. addition to using a cloth moistened with warm water or soapy water, do not use anything else wipe; 5 arm band is only used to measure blood pressure when the volume is tied to the arm, not to dust or corrosive liquids; 6. measurement Do not touch the host, remove the battery when not in use for long periods of time; 7. avoid blood pressure The count is stored in a place of high temperature, humidity, and direct sunlight. Blood pressure values ??and health generally people entered in the elderly, blood pressure generally have a tendency to increase. With age, the blood vessels begin to age, more likely due to obesity, lack of exercise and other factors, cause cholesterol to be put in the blood vessels, so that the loss of elasticity of blood vessels, causing high blood pressure. Hypertension easily accelerate such symptoms of atherosclerosis, caused by diseases such as stroke and myocardial infarction. Therefore, we should understand, whether self-blood pressure in a healthy state. The body's blood pressure all the time in the fluctuations, and therefore develop a regular basis in the habit of measuring blood pressure, is indispensable in our day-to-day health management. Blood pressure, the basics of blood pressure is the blood vessel wall to withstand the pressure of the blood flowing through the arteries. Systolic blood pressure (the most high blood pressure): the internal pressure in the arteries when the heart contraction sends blood. Diastolic blood pressure (hypotension most): the internal pressure in the arteries when the heart dilation of blood return to the heart. In general, the lower the blood pressure in the morning, but over time close to noon to evening hours increased. Summer, lower blood pressure, and blood pressure will be higher in winter. Factory professional production sphygmomanometer, eye massager, beauty instrument, therapeutic equipment, mini massager, welcome to inquire! Contact: Jing Yu Yong Tel: 13,728,829,150 QQ: 2,630,388,876 |
Admin>>>
You are the 7508 visitor
Copyright © GuangDong ICP No. 10089450, Science and Technology Co., Ltd. of Shenzhen Fan children All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7508 visitor
Copyright © GuangDong ICP No. 10089450, Science and Technology Co., Ltd. of Shenzhen Fan children All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility